AWWA JAW39297

$18.00

Journal AWWA – Mechanism of Cryptosporidium, Giardia, and MS2 Virus Removal by MF and UF
Journal Article by American Water Works Association, 09/01/1995

Document Format: PDF

Description

Water quality regulations dealing with microbial removal have increased interest in using microfiltration (MF) and ultrafiltration (UF) as barriers against protozoan cysts and viruses. Consequently, a study was conducted to evaluate the removal of these organisms by a variety of MF and UF membranes and to elucidate removal mechanisms. All of the hollow-fiber membranes evaluated removed Giardia muris cysts and Cryptosporidium parvum oocysts to below detection limits. No cysts or oocysts were detected in the permeate as long as the membrane remained intact. Physical straining of these organisms from the feedwater appeared to be a primary mechanism of action. The extent of virus removal was membrane-specific, with removals ranging from &lt0.5 log to &gt6 logs. Three phenomena appeared to contribute to virus removal: physical sieving or adsorption, cake layer formation, and fouling state of the membrane. The relative contribution of each of these was a function of water quality, time of operation or filtration, and membrane characteristics. Includes 19 references, tables, figures.

Product Details

Edition:
Vol. 87 – No. 9
Published:
09/01/1995
Number of Pages:
15
File Size:
1 file , 23 MB
Note:
This product is unavailable in Ukraine, Russia, Belarus